banner banner

We commit to produce high quality and innovation HDPE pipe material application for water supply system and construction industry.

We aim to contribute to the success of our customers based on strong innovation, concentrating on quality and efficiency, technical service and a global manufacturing platform.

We continue to develop the best quality product to serve the business trends and consumer lifestyle to be more functional and sustainable.

Pipe Product Segments

Pipe product segments is divided into and for 3 main applications which are water supply, construction and infrastructure and industrial and chemical.

Water Supply

  1. Portable Water System

    • HDPE Water pipe PE100

    • HDPE Pipe Fittings

    Mineral Water
  2. Agriculture, Irrigation

    • HDPE Water Pipe PE100

    • HDPE Pipe Fittings

    Mineral Water

Construction / Infrastructure

  1. Conduit and Telecom Pipe

    • HDPE Pipe Fittings

    • HDPE Conduit Pipe

    Conduit, Telecom Pipe
  2. Cable Protection, Corrugated Pipe

    • HDPE Pipe Fittings

    • HDPE Conduit pipe

    • HDPE Corrugated Pipe

    Cable Protection, Corrugated Pipe
  3. Withdrawal Sewerage System

    • HDPE Pipe Fittings

    • HDPE Corrugated Pipe

    Withdrawal Sewerage System

Industrial / Chemical

  1. Gas Distribution Line

    • HDPE Gas Pipe PE100

    Gas Distribution line
  2. Pipe Lining

    • HDPE Gas Pipe PE100

    Pipe Lining

Types of Pipe

Pipe -141606366835.jpeg

Conduit Pipe

High density polyethylene with good mechanical properties. It is resistant to weather conditions and flexible.

Pipe -151606366711.jpeg

Corrugated Pipe

Has good mechanical properties, resistant to weather conditions, flexible and easy for installation

Pipe -161606381500.jpeg

Gas Pipe PE100

It is not brittle and lightweight which makes it easy to install and manage as well as reducing damage during storage.

Pipe -131606366635.jpeg

Pipe Fittings

To be used with pipes and electric system. It is resistance to pressure and weather conditions including is flexible and meets compound requirement of ISO4427.

Pipe -121606366586.jpeg

Water Pipe PE100

Polyethylene pipe with high resistance to pressure and weather conditions. It is also flexible and meets compound requirement of ISO4427.

Certificate

InnoPlus HDPE LLDPE LDPE Plant Certificate
innoplus-certificate

InnoPlus Product International Standard Compliances

InnoPlus and PlastMate HDPE PRODUCT

International Standard Compliances by GRADE
International Standard Compliances by GRADE

FAQ Troubleshooting Pipe

  1. Q : Improper die setting

    A : Adjust the die setting

  2. Q : Improper alignment of die and take-off units

    A : Check for alignment

  3. Q : Hot and cold spots in die profile temp

    A : Check for uniformity in die heating

  1. Q : Maybe due to moisture in resin

    A : - Pre-dry resin before using
    - Reduce screw speed
    - Check for leaking in warehouse facilities, handling and transfer systems

  2. Q : Improper mixing of resin and additives

    A : Increase rpm back pressure for better mixing or decrease mesh of the screen pack for increasing back pressure

  3. Q : Contamination

    A : - Check the for contamination in the resin and the additives applied to the resin
    - Keep resins in clean areas free of moisture and dust

  4. Q : Over heating

    A : Check for the functioning of temperature controller.

  1. Q : Melt temperature too low

    A : - Increase die temperatures
    - Increase extruder temperatures

  2. Q : Contaminates sticking on the mandrel or sizing sleeves

    A : Check for contaminates sticking on mandrel or sizing sleeves

  3. Q : Very high linear extrusion speeds can cause melt fracture at the die

    A : Reduce speeds

  4. Q : If a strip of roughness on underside, then it is caused by uneven water cascading

    A : Direct another cascade from bottom to upward

  5. Q : Misalignment of sleeve and die

    A : Check for alignment

  6. Q : Moisture in resin

    A : - Pre-dry resin before using
    - Reduce screw speed
    - Check for leaking in warehouse facilities, handling and transfer systems

  7. Q : Die gap too narrow

    A : Increase die gap

  1. Q : Sizing devices in adequate or out of shape

    A : Check for sizing devices.

  2. Q : Pipe is too warm when it reaches the haul off unit

    A : Adequate cooling of pipe before reaching the haul off unit

  1. Q : Moisture in resin

    A : - Pre-dry resin before using
    - Reduce screw speed
    - Check for leaking in warehouse facilities, handling and transfer systems

  2. Q : Resin degradation

    A : - Decrease the melt temperature of the resin
    - Increase the screw speed of the lextruder
    - Reduce the back pressure

  3. Q : Dirty die

    A : Remove any dirt or contaminated material lodged within the die head

  1. Q : Excessive melt temperatures

    A : - Reduce back pressure by increasing diameter of adapter to die or die clearances
    - Reduce melt temperature by reducing compression ratio
    - Reduce shear by reducing RPM increasing metering channel depth

  2. Q : Operating die zones too high

    A : Check for the temperature in proper range